Connected equipment cybersecurity

Controllers, PLCs, gateways, equipment you can operate remotely: they save time, but they can also become an entry point. ShoWise helps you find out what is exposed, then fix it without replacing everything.

Review my equipment

Why now

Cyberattacks hit everyone, small and large alike

In mid-October 2026, refrigeration controllers in many French supermarkets were tampered with remotely and forced into defrost, forcing stores to throw away fresh and frozen food. The targets were not office PCs but control equipment reachable remotely.

This scenario is not limited to large retailers. Any equipment you can operate remotely (refrigeration, heating and ventilation, process, PLC) raises the same question: who can reach it, how, and what happens if it is hijacked? The exact circumstances of the attack are a matter for the investigation; the lesson is simple.

Supermarket refrigerated aisle emptied of its products and closed off with red and white tape, with a notice stuck on a glass door
AI-generated illustration: refrigerated aisle emptied and closed off after a cyberattack.

What an audit makes possible

  • Know what can be reached from the Internet: the list of exposed equipment, and how it is reached.
  • See where the industrial network meets the office network: which flows exist today, and which have no reason to.
  • Know who has remote access: manufacturer, maintenance provider, on-call staff, with what means and what rights.
  • Spot weak settings: factory-default passwords, unnecessary services, available updates.
  • Identify old or fragile equipment that can no longer be updated, and so has to be protected by what surrounds it.
  • Know whether you could restart quickly after an incident: are the controller and regulator configurations backed up?
  • Get a prioritised action plan: where to start, and what can wait.

What ShoWise does next

  • Segregate the network: separate the industrial network from the office network and, where needed, the industrial sectors from each other, letting through only the flows that are needed.
  • Close what is exposed: filter inbound access, remove whatever does not need to be reachable.
  • Secure remote access: controlled and logged access for the manufacturer and the maintenance provider, without exposing the installation on the Internet.
  • Fix weak settings: passwords, unnecessary services, available updates.
  • Back up the configurations of controllers and regulators.
  • Assist after an incident on the equipment side: secure return to service, after preserving what the investigation needs.
  • Hand over the documentation: network diagram, rules applied, backed-up configurations.
Internet Office network Industrial · sector 1 Industrial · sector 2 MES / MOM Authorised flows only No communication Controlled remote access
Illustration: segregated zones, controlled remote access, flows cut to what is strictly necessary.

The audit in practice

What a ShoWise audit covers

An audit is first a read-only review: we observe, we change nothing. It can be complemented by active tests, only if you decide so. Here is the framework.

  1. Written scope

    Before any visit, a signed document sets what is examined, whether active tests are allowed (and under which conditions), and the confidentiality of the findings.

  2. What is examined

    Equipment (PLCs, controllers, gateways), industrial network, interface with office IT, remote access. Office IT is only looked at where it meets the industrial side.

  3. Read-only (default)

    Review of configurations and diagrams, passive observation of the network. Nothing is changed, nothing is sent to the equipment: production is not disturbed.

  4. Active tests (express agreement only)

    Network scans, active search for weaknesses. These tests can disturb, or even crash, fragile or old equipment. They are only run with your express written agreement, and only if production allows it (planned stop, test bench, equipment known to cope with them).

  5. What you receive

    A dated report: what was found, ranked by priority, and a realistic action plan. It describes the state on the day of the visit.

  6. What it is not

    Neither a regulatory or qualified audit, nor a compliance certificate (NIS2, ISO 27001, IEC 62443), nor a guarantee of never being attacked.

Frequently asked questions about equipment cybersecurity

Do I have to replace everything to secure my installation?

No, in most cases. We build on what is in place: network segregation, access control, equipment settings. Replacement is only proposed when there is no other reasonable way.

My equipment is old: is that a problem?

Not necessarily. Much industrial equipment can no longer be updated. We then protect it through what surrounds it: network isolation, filtering, controlled access.

Will an audit disrupt my production?

Not by default: the audit is read-only (review of configurations and diagrams, observation of the network) and changes nothing. There is an optional part of active tests (scans, search for weaknesses), and that part can disturb, or even crash, fragile or old equipment. It is therefore only run with your express written agreement, and only if production allows it (planned stop, test bench, equipment known to cope with it).

Is ShoWise certified or qualified (ANSSI, PASSI)?

No. ShoWise is not a provider qualified by ANSSI (the French national cybersecurity agency). Drawing on its experience in connected systems, ShoWise works as an expert on equipment it knows well (PLCs, electronics, industrial networks) and, to structure its findings, draws on the ANSSI guides on industrial systems security, which does not amount to a qualification. It also talks to CCI Val-d'Oise to identify the labels or recommendations that can reassure you.

My installation has already suffered an incident: what should I do?

First notify your insurer and, if needed, the cybermalveillance.gouv.fr assistance platform, and do not reset anything until the elements useful to the investigation have been preserved. ShoWise then works on the equipment: secure return to service and fixes to prevent a repeat. ShoWise does not run the investigation.

Can I be sure never to be attacked again?

No, no approach guarantees zero risk. We reduce what is exposed and limit the possible damage, starting with the most important points.

Doubts about your connected equipment?

Describe your installation, even in a few lines.
An audit tells you what is exposed, and where to start.

Review my equipment